Found inline power controller write failure

ERROR on my switch 3750, here the message on booting:

Waiting for Stack Master Election…
POST: Inline Power Controller Tests : Begin
POST: Found inline power controller write failure, inst 11
POST: Inline Power Controller Tests : End, Status Failed

POST: Inline Power feature is disabled on this switch

POST: PortASIC CAM Subsystem Tests : Begin
POST: PortASIC CAM Subsystem Tests : End, Status Passed

POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed

Election Complete
Switch 1 booting as Master
Waiting for Port download…Complete
————–

I use 3750 for 16 PCs and 12 IP Phone 7960G. PC client still work but I can’t use or activate PoE on my IP Phone anymore. I try to give command = “power inline consumption <miliwatts range 4000 – 15400>” but still failed.

does anyone know whats the problem??

update:

the answer here on sadikhov forum..

Advertisement

3 responses to “Found inline power controller write failure

  1. Hi, i Have the same problem with my CE500 i contact the TAC guys and they told me that the power supplier for PoE is dammaged and i need to buy an smartnet

    Is is not so urgent you can buy SMB SA service

    regards

  2. This is a hardware problem. I have fixed a few switches with that problem WS-C3760-48PS-S and WS-C3560-48PS-S. Check my services auction on eBay. Item number 320264282221.

    Regards.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s

This site uses Akismet to reduce spam. Learn how your comment data is processed.